Sign In | Join Free | My burrillandco.com
Home > Ventilator Accessories >

Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE

    Buy cheap Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE from wholesalers
     
    Buy cheap Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE from wholesalers
    • Buy cheap Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE from wholesalers
    • Buy cheap Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE from wholesalers
    • Buy cheap Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE from wholesalers
    • Buy cheap Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE from wholesalers
    • Buy cheap Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE from wholesalers
    • Buy cheap Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE from wholesalers

    Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE

    Ask Lasest Price
    Brand Name : Nihon Kohden
    Certification : CE
    Price : as discussed
    Payment Terms : T/T, Western Union
    Supply Ability : 1000pcs / day
    Delivery Time : 2-3 days
    • Product Details
    • Company Profile

    Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE

    Medical equipment Mainstream Nihon Kohden EtCO2 Sensor


    product description

    Item
    Value
    Vailable Brand
    Nihon Kohden
    MOQ
    1PCS
    Color
    Grey
    Sample
    Provide sample
    Service
    ODM/OEM

    Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE

    Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE

    Specification

    Sample Flow Rate
    Range:50-150 ml/min; Accuracy:±20% ; Default: 75 ml/min
    Principle of Operation
    Non-dispersive infrared, dual wavelength, no moving parts
    Initialization Time
    Capnogram displayed in less than 4 seconds, at an ambient temperature of 25℃, full specifications within 2 mintues
    CO2 measurement Range
    0-114 mmHg ; 0-15% ; 0-15.2 kPa
    CO2 Response Time
    Includes Transport time and rise time.Less than 2 seconds, at 150 ml/min sampling flow
    Less than 3 seconds, at 100 ml/min sampling flow
    Less than 4 seconds, at 50 ml/min sampling flow
    CO2 Resolution
    0.2 mmHg @ 0-59 mmHg ; 0.5mmHg @60-114 mmHg
    CO2 Accuracy
    0-40 mmHg ± 2 mmHg41-70 mmHg ± 5% of reading
    71-100 mmHg ± 8% of reading
    101-114 mmHg ±10% of reading
    Above 80 reaths per mintue ±12% of reading
    * Note:Gas temperature at 25℃
    CO2 Stability
    Short Term Drift : Drift over three hours shall not exceed 1 mmHg maximumLong term Drift : Accuracy specification will be
    maintained over a six hour period
    CO2 Noise
    RMS noise of the sensor shall be less than or equal to 0.5 mmHg at 5% CO2
    Sampling Rate
    100Hz
    Respiration Rate Range
    2 to 150 breaths per minute
    Respiration Rate Accuracy
    ± 1 breath
    Calibration
    No Routine user calibration required
    EtCO2 Calcuation
    Method: peak of the expired CO2 waveform
    Inspired CO2 Measurement
    Method: Lowest reading of the CO2 waveform in the previous 20 seconds
    Temperature
    Operation : 0 to 40℃ ; Storage :-40 to 70℃ ; Transport :-40 to 70℃
    Humidity
    Operation :10 to 90 % RH, Non-condensing ; Storage :10 to 90 % RH, Non-condensing.
    Transport: 10 to 90 % RH, Non-condensing.
    Atmospheric Perssure
    Operating :400-800 mmHg ; Storage :400-800 mmHg ; Transport :400-800 mmHg
    Water Resisitance
    IPX4-Splash-Proof- sensor only
    Voltage Requirements
    5 VDC ±5% ; Ripple not to exceed 100.0mV
    Power Raing
    < 1.2W Typical; < 2.0 W Warm-up
    Sensor Weight
    < 250 g
    Sensor Size
    Deep*Wide*High 102*62*38mm
    Cable Length
    75cm

    Characteristics:

    Long-term stability, non-dispersive infrared technology with two wavebands
    Long service life, infrared black body light source with MEMS
    Accurate Results, with built-in temperature, atmospheric pressure, compensation algorithm for the balance gas
    Calibration-free, patented calibration algorithm without the need for calibration
    Low sampling flow rate, the minimum sampling flow rate 50ml/min
    Easy to operate, plug-in measure
    Low cost in usage and storage
    Specification
    Respiration rate range: 2~150 breath/minute
    Electric power supply: DC 5V
    Power Consumption: 1.2W
    Usage Environment: 0~40ºC, 10~90% RH, without condensation
    Storage Environment: -40~70ºC, <90% RH, without condensation